Advertisement

FX2N-32DP-IF Profibus-DP Interface Unit
8.3

Check Error Status of the 32DP-IF

8.3.1

Error Status in D8029

Table 8.5: Error Status in D8029
Bit No.
Bit 0
Bit 1
Bit 2
Bit 3 ~ 5
Bit 6
Bit 7
Bit 8, 9
Bit 10
Bit 11
Bit 12 ~ 14 Reserved
Bit 15
Description
general error
No general error
Reserved
Power supply is
Power fail
normal
Reserved
I/O bus error
No I/O bus error
Operation error
No operation error
Reserved
Configuration
configuration error
data valid
Parameter data
Parameter error
valid
RUN/STOP
RUN/STOP status
switch is in RUN
position
0 (OFF)
This bit is ON if one or more error bits (bit 2, 6,
7) are ON. Check bit 2, 6 and 7 in D8029.
Power supply failure
I/O bus error occurred. Check extension bus
cable of I/O extension units/blocks and error
code in D8060.
Operation error occurred. Check extension bus
cable of special function blocks, and DP-master
parameter, and error code in D8067 and
D8068.
Invalid configuration data received. Check con-
figuration of 32DP-IF in the DP-master and
D8040 ~ D8055.
Invalid parameter data received. Check param-
eter of 32DP-IF in the DP-master and D200 ~
D299, and error code in D8064and D8068.
RUN/STOP switch is in STOP position
Diagnostics 8
1 (ON)
8-3