  • Page 1 51AKS OWNER’S MANUAL...
  • Page 2: Table Of Contents

    This manual applies to the following models Contents Stand-alone Split Page Control panel ......... 1 51AKS 085--- 51AKS 010--- Accessories supplied ......2 General information ......2 51AKS 185--- 51AKS 013--- Correct use ..........3 Preparing to use (stand-alone) ..4/5 Preparing to use (split) ......
  • Page 3: Accessories Supplied

    (such as smell of burning) and call Carrier further consultation even after installation. Service for further instructions. • This unit complies with the following •...
  • Page 4: Correct Use

    Correct use E N G L I S H The outdoor unit may be attached to the back of the indoor Do not obstruct the sides, front and rear grille with curtains or unit with the flexible tube neatly coiled, but never kinked, to other objects.
  • Page 5: Cooling With Dehumidification

    Preparation for: STAND-ALONE cooling with dehumidification Air flow Air flow To open the window as little as possible, Install the flexible hose onto the air conditioner. To improve the air place the air outlet conditioner performance make sure that: Move the air conditioner close vent onto the - the internal tips of the flexible hose are turned as shown in the to the window, stretching the...
  • Page 6: Heating

    Preparation for: STAND-ALONE dehumidification E N G L I S H In certain applications, when a floor drain To empty the tank, switch the unit off may be available it may be easier to use and remove the plug from the power the drain tube to remove the condensate •...
  • Page 7 Preparation for: SPLIT cooling with dehumidification Move the air conditioner close to the window. Outdoor section may be placed on the ground or a balcony or Place the outdoor unit outside, ensuring that air can hung from a window sill using the straps and bracket circulate freely around and through the unit.
  • Page 8 Preparation for: SPLIT dehumidification E N G L I S H To empty the tank, switch the unit off Position both the indoor and outdoor The dehumidification only function and remove the plug from the power units in the room you want to should be used if you want to remove supply socket.
  • Page 9: Cooling With Dehumidification

    CONTROL PANEL Cooling with dehumidification 10 11 T I M E R F A N M O D E AUTO • Switch on the unit by pressing button 1 • Using the fan speed selector, button 3, select the fan speed which may be low, high or automatic.
  • Page 10 T I M E R F A N M O D E AUTO Mod. 51AKS 010---, 013---, 015--- Mod. 51AKS 085--- • Press button • Select the fan speed by pressing button Speeds which can be selected are: low and high.
  • Page 11: Timer Programming

    CONTROL PANEL Timer programming Timer programming With the button the air conditioner can be programmed • The air conditioner has now been programmed to when switching on to switch on automatically at the preset time. switch on at 10.30 a.m. •...
  • Page 12: Quick-Connect Couplings

    E N G L I S H ...use of quick-connect couplings for fixed installation. Models 51AKS 010---, 013---, 015--- are provided with quick coupling connections that allow the unit to be disconnected up to a maximum of six times without impairing the performance of the air conditioner.
  • Page 13: In Case Of

    In case of… If the unit appears not to be operating ...the main switch is on, there are no ... the operating instructions in the correctly, before calling a service breaks in the electrical cable and that the technician please check that... literature have been followed…...
  • Page 14: Cleaning

    Cleaning E N G L I S H Periodically clean the air filters in the sides of the unit. First clean the filters with a vacuum cleaner then rinse To pull out the filters from their position use the tab on and dry the filters.