  • Page 1 METROLOGIC INSTRUMENTS, INC. ® MS9500 Voyager Series Single-Line Hand-Held Laser Scanner Installation and User’s Guide...
  • Page 3 Copyright © 2004 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
  • Page 4: Table Of Contents

    ABLE OF ONTENTS Introduction... 1 Scanner and Accessories... 2 Operation Test... 4 Installing the Scanner to the Host System MS9520-00/9/11/14/41 Keyboard Wedge MS9520-47 and MS9540-47... 6 Stand Alone Keyboard ... 7 Integrated USB Full Speed MS9520-40 and MS9540-40 ... 8 Low Speed POS MS9520-39 and MS9540-39 ...
  • Page 5 Mechanical ... 32 Electrical... 32 Environmental ... 32 Default Settings ... 33 Scanner and Cable Terminations Scanner Pinout Connections ... 38 Cable Connector Configurations ... 40 Limited Warranty ... 42 Laser and Product Safety ... 43 Patents ... 45 Index... 46...
  • Page 7: Introduction

    CodeGate works hand-in-hand with Metrologic’s patented automatic-triggering scheme. Simply present a bar code to the scanner; the high-visibility 650-nanometer laser is automatically activated allowing the user to easily select the bar code to be scanned. Press the CodeGate button and the data is transmitted to the host system.
  • Page 8: Scanner And Accessories

    Part # MS9500 Voyager Series Scanner 00-02544 MetroSelect Single-Line Configuration Guide MS9500 Voyager Series Single-Line Hand Held Laser 00-02410 Scanner Installation and User’s Guide Available on the Metrologic website - www.metrologic.com Part # AC to DC Power Transformer- Regulated 5.2VDC @ 650 mA output.
  • Page 9 CANNER AND CCESSORIES Part # USB Power/Communication Cable, 53-53213 3 m (10’) coiled cord, long strain relief, gray USB Power/Communication Cable, 5 m (10’) coiled cord, long strain relief, gray 53-53214 Not for use with Low Speed USB scanners. Use with Full Speed USB scanners only. MX009-2** MX009 USB Converter Cable Metrologic Voltage Converter Cable...
  • Page 10: Operation Test

    Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
  • Page 11: Installing The Scanner To The Host System

    Laser Emulation Mode. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
  • Page 12: Keyboard Wedge Ms9520-47 And Ms9540-47

    Representative if you require an external power supply. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
  • Page 13: Stand Alone Keyboard

    Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
  • Page 14: Integrated Usb Full Speed Ms9520-40 And Ms9540-40

    Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.
  • Page 15: The Powerlink Cable Disconnecting

    OWER ISCONNECTING THE Before removing the cable from the scanner, Metrologic recommends that the power on the host system is off and the power supply has been disconnected from the PowerLink cable. Locate the small ‘pin-hole’ on the top of the unit near the bottom of the Voyager logo.
  • Page 16: The Ms9540 Voyagercg ® Series

    MS9540 V OYAGER OW TO ATE AND THE Figure 10a. HREE ODES OF PERATION Auto Trigger, In-Stand • Auto-triggers while in the stand • Bar code is automatically decoded and transmitted CodeGate, Out-of-Stand • CodeGate activates when removed from the stand •...
  • Page 17: Stand Kits

    TAND Free Standing Kits #46-46128 Contains: a. Stand ( 36-00454)...Qty 1 MLPN b. Apron ( 50-50440) ...Qty 1 MLPN c. Screw, M3 x 6 mm ( MLPN d. Washer, #5 x .5 OD ( MLPN e. Stand Anchor ( 50-50449) ...Qty 1 MLPN f.
  • Page 18 SSEMBLING THE There are two options for assembling the stand. The first option is a self- supporting stand that can be moved freely about on the countertop. The second option is used if the stand will be bolted or hard-mounted to the countertop. Stand Option 1: Self-Supported Stand Kit #46-46128 Step 1 Slide the apron (...
  • Page 19: Assembly

    SSEMBLING THE Stand Option 2: Hard-Mount Kits #46-46128, #46-46351 and MS951 Stand Replacements Anchor from Kit #46-46128 Base Assembly from Kit #46-46351 or MS951 Stand Base Figure 21. Figure 22. Figure 23. Figure 24. Figure 25. TAND Step 3 Screw the stand anchor ( onto the base assembly until it sits flush.
  • Page 20 SSEMBLING THE Wall Mount, Option 1: For Kit #46-46433 or #46-46508 Step 1 Drill two #39 pilot holes 3.00” apart. Step 2 Attach the Wall Mount Hanger to the wall with the two #8 wood screws provided. Wall Mount, Option 2: Kit #46-46508 Step 1 Attach the Wall Mount Base to the Wall...
  • Page 21: Scanner Parts

    CANNER ARTS Red LED** Green LED** Output Window This feature is not available on the MS9520. ** In some custom units the standard green LED has been replaced with a blue LED and the red LED has been replaced with a white LED. Yellow LED CodeGate Button MS9500 Top View...
  • Page 22: Audible Indicators

    When the Voyager is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the beeper tone, refer to the MetroSelect Single-Line Configuration Guide or MetroSet2’s help files.
  • Page 23: Visual Indicators

    The MS9520 has two LED indicators (green* and red*) located on the head of the scanner. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner.
  • Page 24: Failure Modes

    Return the unit for repair to an authorized service center. Three Beeps – on power up If the scanner beeps 3 times on power up then the non- volatile memory (NovRAM) that holds the scanner configuration has failed. If the scanner does not respond after reprogramming, return the scanner for repair to an authorized service center.
  • Page 25: Programming Modes

    String Sent to Scanner = 02h 31h 30h 30h 31h 30h 34h 03h (All values are hexadecimal). If the command sent to the scanner is valid, the scanner will respond with an [ack]. If the command sent to the scanner in invalid, the scanner will respond with a [nak].
  • Page 26 This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits settings that are configured in the scanner. The default settings of the scanner are 9600, Space, 2, 7 respectively. If a command is sent to the scanner to change any of these settings, the change will NOT take effect until after serial program mode is exited.
  • Page 27: Abbreviated Ascii Table

    The scanner will beep three times! This example illustrates two important points. First, if an invalid command is sent from the host, the scanner responds with a [nak] and the end-user must start over from the beginning. Second, if a command is sent to change the Baud Rate, the new baud rate does not take effect until after the end-user exits program mode.
  • Page 28: Upgrading The Flash Rom Firmware

    Press the button to upgrade the scanner, the unit will go into a “flash mode” – both the green* and red* LEDs will be on. The user can follow the progress of the upgrade by watching the screen for details.
  • Page 29: Labels

    ABELS Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE and caution information. The following is an example of this label: EVITER TOUTE EXPOSITION-Lumiere laser emis par cette overture AVOID EXPOSURE –Laser light is emitted from this aperture...
  • Page 30: Depth Of Field

    EPTH OF IELD mils Figure 31. Minimum Bar Code Element Width...
  • Page 31: Ir Activation

    IR A CTIVATION Figure 32.
  • Page 32: Applications And Protocols

    PPLICATIONS AND The model number on each scanner includes the scanner number and factory default communications protocol. Scanner Version Identifier MS9520 MS9540 The MS9520/9540 Keyboard Wedge Series (-47) is designed for keyboard emulation only. Many RS232 programmable functions available in other Metrologic scanners are also available as keyboard wedge functions.
  • Page 33: Troubleshooting Guide

    ROUBLESHOOTING The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. Symptoms All Interfaces The unit has no LEDs, beep or laser. At power up the unit beeps 2 times and alternately flashes the LEDs.
  • Page 34 Solution Verify that the bar code being scanned falls into the programmed criteria. The scanner defaults to a minimum of 3 character bar code. If the unit is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly.
  • Page 35 Caps Lock. Try operating the scanner in Alt mode. Check to make sure that the baud rate and parity of the scanner and the communication port match and that the program is looking for “RS232” data. Check to make sure that the unit is connected to the correct com port on the host device.
  • Page 36: Rs232 Demonstration Program

    This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the COM port is working, and the scanner is working. If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working.
  • Page 37: Design Specifications

    ESIGN PECIFICATIONS PERATIONAL Light Source Laser Power: Depth of Scan Field: Scan Speed: Scan Pattern: Minimum Bar Width: Infrared Activation: Decode Capability System Interfaces Print Contrast: Number Characters Read: Roll, Pitch, Yaw: Beeper Operation: Visual Indicators: Default Settings In some custom units the standard green LED has been replaced with a blue LED and the red LED has been replaced with a white LED.
  • Page 38: Mechanical

    ESIGN PECIFICATIONS ECHANICAL Length: Width: Depth: Weight: LECTRICAL Input Voltage: Power: Current: DC Transformers: Laser Class: EMC: NVIRONMENTAL Temperature: Humidity: Light Levels: Shock: Contaminants: Ventilation: Specifications subject to change without notice. MS9500 Series Specifications 198 mm (7.8”) Handle - 45 mm (1.8”), Head - 78 mm (3.1”) 40 mm (1.6”) 149 g (5.25 oz) 5VDC ±...
  • Page 39: Default Settings

    All default parameters of the scanner have an asterisk ( * ) marked in the default column. If an asterisk is not in the default column then the default setting is off or disabled.
  • Page 40 EFAULT ETTINGS Parameter Mod 43 Check on Code 39 MSI-Plessy 10/10 Check Digit MSI-Plessy Mod 10 Check Digit Paraf Support ITF ITF Symbol Lengths Minimum Symbol Length Symbol Length Lock Bars High as Code 39 Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS...
  • Page 41 EFAULT ETTINGS Parameter Same symbol rescan timeout: 750 msecs Same symbol rescan timeout: 875 msecs Same symbol rescan timeout: 1000 msecs No Same symbol timeout Infinite Same symbol timeout Inter-character delay Program able in 1 msec steps (max 255 msecs) Number of scan buffers (maximum) Transmit UPC-A check digit...
  • Page 42 EFAULT ETTINGS Parameter Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Carriage Return Line Feed-Disabled by default in KBW Tab Prefix Tab Suffix “DE” Disable Command “FL” Laser Enable Command DTR Handshaking support RTS/CTS Handshaking Character Message RTS/CTS XON/XOFF Handshaking ACK/NAK...
  • Page 43 EFAULT ETTINGS Parameter 100 msec to Find Supplement Programmable in 100 msec steps (max 800 msec) Coupon Code 128 † Programmable Code Lengths † Code Selects with programmable Code Length Locks Programmable Prefix characters Suffix characters Prefixes for Individual Code types Editing Inter Scan-Code delay programmable...
  • Page 44: Scanner And Cable Terminations

    Scanner Pinout Connections The MS9520 and MS9540 scanner interfaces terminate to a 10-pin modular jack. The serial # label indicates the interface enabled when the scanner is shipped from the factory. ERMINATIONS RS232C and Light Pen Emulation Ground RS232 Transmit Output...
  • Page 45 CANNER AND ABLE MS9520/40-9 OCIA Function Ground RS232 Transmit Output RS232 Receive Input RDATA RDATA Return Clock In Clock Out Clock in Return/Clock out Rtrn +5VDC Shield Ground MS9520/40-00 Laser Emulation Function Ground RS232 Transmit Output RS232 Receive Input Flip Sense/Start of Scan Output Proximity Detect/Trigger Emulation Output...
  • Page 46: Cable Connector Configurations

    CANNER AND ABLE Cable Connector Configurations (Host End) “Standard” PowerLink Cable 53-53xxx coiled or 54-54xxx straight Function Shield Ground RS232 Transmit Output RS232 Receive Input DTR Input/Light Pen Source Power/Signal Ground Light Pen Data (DSR Out for -14 interfaces) CTS Input RTS Output +5VDC Stand Alone Keyboard PowerLink...
  • Page 47 CANNER AND ABLE Cable Connector Configuration (Host End) Keyboard Wedge PowerLink Cable 53-53002 or 54-54002 Function Keyboard Clock Keyboard Data No Connect Power Ground +5 Volts DC Function PC Data No Connect Power Ground +5 Volts DC PC Clock No Connect Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other.
  • Page 48: Limited Warranty

    EVENT SHALL ANY LIABILITY OF METROLOGIC EXCEED THE ACTUAL AMOUNT PAID TO METROLOGIC FOR THE PRODUCT. METROLOGIC RESERVES THE RIGHT TO MAKE ANY CHANGES TO THE PRODUCT DESCRIBED HEREIN. North America Headquarters Metrologic Instruments, Inc. 90 Coles Road Blackwood, NJ 08012-4683 Germany...
  • Page 49: Laser And Product Safety

    ASER AND RODUCT Notice This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 50 Non guardate mai il raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Facendolo potete esporVi ad una esposizione laser rischiosa.
  • Page 51: Patents

    ATENTS Patent Information This METROLOGIC product may be covered by one or more of the following US Patents: US Patent No. 4,958,984; 5,081,342; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,591,953; 5,616,908; 5,627,359; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,811,780; 5,825,012; 5,828,048;...
  • Page 52: Index

    NDEX AC Input/Outlet...5, 6, 7 Accessories ...2 Adapter...2 Approvals ...23 Audible ...16–18 Beep... 4, 16–18, 20, 21, 22, 27–29, 34 Cable... 2–3, 4–8, 27–29, 38–41 Adapter ...2 Communication...2–3, 4–8, 22, 29, 33, 38–41 Pin Assignments ...38–41 PowerLink ... 1, 2–3, 4–7, 9, 22, 38–41 USB ...3, 8 Caution...23, 44...
  • Page 53 NDEX Parameter...33–37 Parts ...2, 15 Pin Assignments...38–41 Port...6 Power Supply ...4–8, 9, 22, 27 PowerLink...4–7, 41 Programming... 4, 19, 20, 26, 29 Razzberry tone ...34 Razzberry Tone...16–18 Red LED... 4, 16–18, 22, 27–29 Repair...42 RMA ...42 RS232 ... 1, 2, 5, 26, 29, 30 Service ...3, 42 Specifications ...32 Stand...2, 3...
  • Page 54 OTES...
  • Page 56 March 2004 Printed in the USA 0 0 - 0 2 4 1 0 E...