Metrologic MS9500 Voyager Series Installation And User Manual

Metrologic MS9500 Voyager Series Installation And User Manual

Single-line hand-held laser scanner
Hide thumbs Also See for MS9500 Voyager Series:

Advertisement

MS9500 Voyager™ Series
Single-Line Hand-Held Laser Scanner
Installation and User's Guide

Advertisement

Table of Contents
loading

Summary of Contents for Metrologic MS9500 Voyager Series

  • Page 1 MS9500 Voyager™ Series Single-Line Hand-Held Laser Scanner Installation and User’s Guide...
  • Page 2 Email: info@br.metrologic.com Copyright 2000 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.
  • Page 3 January 2000...
  • Page 4: Table Of Contents

    Introduction ... 1 Scanner and Accessories ... 2 Quick Start... 3 Installing the Scanner to the Host System ... 4 Disconnecting PowerLink Cables from the Scanner... 5 How to Use CodeGate – MS9540 Only... 6 Assembling the Stand ... 7 Scanner Parts ...
  • Page 5 Table of Contents (continued) Appendix A Design Specifications... 29 Appendix B Default Settings... 30 Appendix C Pin Assignments ... 35 Appendix D Warranty and Disclaimer... 38 Appendix E Notices... 39 Appendix F Patents... 41 Addendum ... 42 Index... 43...
  • Page 6: Introduction

    Introduction The Voyager™ MS9500 Series single-line hand-held scanners include both the MS9520 and MS9540. The Voyager MS9540 features Metrologic’s patented CodeGate™ technology. CodeGate is an intuitive scanning system that is ideal for all scanning applications, including menu-scanning, point-of-sale, document processing, and inventory control.
  • Page 7: Scanner And Accessories

    Scanner and Accessories The following list of parts may or may not be included in the MS9500 kit. Voyager MS9520 Single-Line Laser Scanner, or Voyager MS9540 – CodeGate™ Single-Line Laser Scanner AC to DC Power Transformer – Regulated 5.2VDC @ 650 mA output .
  • Page 8: Quick Start

    4. When the Voyager is ready to scan, the green LED will turn on, the red LED will flash and the scanner will beep once. 5. Place a bar code in front of the scanning window. The scanner will beep once and flash the red LED if the bar code was successfully decoded.
  • Page 9: Quick Start

    3. Connect the PowerLink cable to the proper port on the host system. 4. Turn on the host system. Note: Plugging the scanner into a port on the host system does not guarantee that scanned information will be communicated properly to the host system.
  • Page 10: Disconnecting Powerlink Cables From The Scanner

    2. Bend an ordinary paperclip into the shape shown above. 3. Insert the paperclip (or other small metallic pin) into the small ‘pin- hole’. 4. You will here a faint ‘click’. Pull gently on the strain-relief of the PowerLink cable and it will slide out of the scanner.
  • Page 11: How To Use Codegate - Ms9540 Only

    How to Use CodeGate – MS9540 Only Two Modes of Operation Auto-trigger while in the stand Bar code is automatically decoded and transmitted CodeGate activates when removed from the stand Bar code data is transmitted when the CodeGate button is pressed to trigger activates...
  • Page 12: Assembling The Stand

    Assembling the Stand Kit #46-46055 Contains: Stand Apron Screw, M3 x 6 mm long Washer, #5 x .5 OD Stand Anchor Wood Screw, #8 Round Head Base There are 2 options for assembling the stand. The first option allows the stand to be self-supporting and moved freely or placed anywhere on the countertop.
  • Page 13 Assembling the Stand (continued) Stand Option 2: Hard-mounted to countertop 2.00 in 2.00 Anchor #8 Wood Screw Base Step 1 Drill four #39 holes in the countertop. Step 2 Secure the base (mlpn 36-36080) to the countertop with the four #8 wood screws (mlpn 18-18057) provided.
  • Page 14: Scanner Parts

    Scanner Parts Green, Yellow and Red LEDs CodeGate Button* Output Window Stand Cable Connection Stand Apron *This feature is not available on the MS9520...
  • Page 15: Audible Indicators

    Audible Indicators When the Voyager is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect Programming Guide MLPN 2407.
  • Page 16 This is a failure indicator. Refer to “Failure Modes” on page 13.
  • Page 17: Visual Indicators

    Visual Indicators There are three LED indicators (green, red and yellow) located on the head of the MS9500. When the scanner is on, the flashing or stationary activity of the LEDs indicates the status of the current scan and the scanner.
  • Page 18 Visual Indicators (continued) Alternating Flashing of Green and Red This indicates the scanner is program mode. A razzberry tone indicates that an invalid bar code has been scanned while in this mode. Steady Red, Green off This indicates the scanner may be waiting for...
  • Page 19: Failure Modes

    Return the unit for repair to an authorized service center. Three Beeps – on power up If the scanner beeps 3 times on power up then, the non- volatile memory (NovRAM) that holds the scanner configuration has failed. Return the unit for repair to an...
  • Page 20: Programming Modes

    Programming Modes The MS9500 Voyager has 3 modes of programming. Bar Codes: Voyager can be configured by scanning the bar codes located in the METROSELECT® Configuration Guide (MLPN 2407). Please refer to this guide for instructions. This manual can be downloaded for FREE from Metrologic’s website (www.metrologic.com).
  • Page 21 8. This mode uses the current Baud Rate, Parity, Stop Bits and Data Bits settings that are configured in the scanner. The default settings of the scanner are 9600, Space, 2, 7 respectively. If a command is sent to the scanner to change any of these settings, the change will NOT take effect until after serial program mode is exited.
  • Page 22 Exit Program Mode The scanner will emit a long beep! This example illustrates two important points. First, if an invalid command is sent from the host, the scanner responds with a [nak] and the end-user must start over from the beginning.
  • Page 23: Upgrading The Flash Rom Firmware

    PC, launches the Meteor program, and blasts off to new software upgrades. Each MS9500, regardless of the version number or communication protocol, can be upgraded. In other words, all RS232 (-41), keyboard wedge (-47), light pen (-41), OCIA (-9) and IBM 468X/469X (-11) units can be upgraded.
  • Page 24: Labels

    Labels Each scanner has a label on the back of the unit. This label has the model number, date of manufacture, serial number, CE and caution information. The following is an example of this label: AVOID EXPOSURE laser light emitted from this aperture...
  • Page 25: Depth Of Field

    7.1” [180 mm] 8.5” [216 mm] 9.8” [249 mm] 11.7” [297 mm] Width of Scan Field Minimum Bar Code Element Width Distance: Scanner Face 0.0” [0 mm] 1.0” [25.4 mm] 2.0” [51 mm] 2.5” [64 mm] 5.0” [127 mm] 6.5” [165 mm] 8.0”...
  • Page 26: Ir Activation

    IR Activation 2.5” [64 mm] Scan Width at Face Short Range IR Long Range IR Width of Scan Field 6.2” [158 mm] 12.6” [320 mm] Distance From Face 0.0” [0 mm] 4.0” ± 1.0” [102 mm ± 25.4mm] 11.0” ± 2.0” [229 mm ±...
  • Page 27: Maintenance

    Maintenance Smudges and dirt can interfere with the proper scanning of a bar code. Therefore, the output window will need occasional cleaning. Spray glass cleaner onto lint free, non-abrasive cleaning cloth. Gently wipe the scanner window.
  • Page 28: Applications And Protocols

    MS9540 MS9520 MS9540 The MS9500 Series Hand-Held Laser Scanner with built-in PC Keyboard Wedge Interface is designed to be used for Keyboard emulation only. Many RS-232 programmable functions available in other Metrologic scanners are also available as keyboard wedge functions.
  • Page 29: Trouble Shooting Guide

    Trouble Shooting Guide The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-Metro or 1-800-436-3876 to preserve the limited warranty terms. All Interfaces MS9500 Series Troubleshooting Guide Symptoms Possible Causes No LEDs, beep No power is being supplied...
  • Page 30 (Typical of Non-UPC/EAN codes) The scanner defaults to a minimum of 3 character bar code If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly Verify that the scanner’s data format...
  • Page 31 NOT for others been printed incorrectly of the same bar code symbology Scanner beeps at some bar codes The scanner is not and NOT for others configured correctly for of the same bar this type of bar code code symbology...
  • Page 32 Solution Make sure the scanner is configured for the appropriate mode. Check internal jumper Make sure that the proper PC type AT, PS2 or XT is selected. Verify correct country code and data formatting are selected.
  • Page 33 Solution Check to make sure that the baud rate and parity of the scanner and the communication port match and the program is looking for “RS-232” data Check to make sure that the baud...
  • Page 34: R232 Demonstration Program

    This program is for demonstration purposes only. It is only intended to prove that cabling is correct, the com port is working, and the scanner is working. If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working.
  • Page 35: Design Specifications

    Appendix A – Design Specifications Operational Light Source Laser Power Depth of Scan Field Scan Speed Scan Pattern Minimum Bar Width InfraRed Activation Decode Capability System Interfaces Print Contrast Number Characters Read Roll, Pitch, Yaw Beeper Operation Indicators (LED) Mechanical Length Width-Handle Width-Head...
  • Page 36: Default Settings

    Appendix B – Default Settings Many functions of the scanner can be “programmed” – that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk (*) in the charts on the following pages.
  • Page 37 Appendix B – Default Settings (continued) PARAMETER Mod 43 Check on Code MSI-Plessy 10/10 Check Digit MSI-Plessy Mod 10 Check Digit Paraf Support ITF ITF Symbol Lengths Minimum Symbol Length Symbol Length Lock Bars High as Code 39 Spaces High as Code 39 Bars High as Scanned Spaces High as Scanned DTS/SIEMENS...
  • Page 38 Appendix B – Default Settings (continued) PARAMETER Same symbol rescan timeout 750 msecs Same symbol rescan timeout 875 msecs Same symbol rescan timeout: 1000 msecs No Same symbol timeout Infinite Same symbol timeout Inter-character delay Program able in 1 msec steps (max 255 msecs) Number of scan buffers Transmit UPC-A check...
  • Page 39 Appendix B – Default Settings (continued) PARAMETER Transmit Sanyo ID Characters Nixdorf ID LRC Enabled UPC Prefix UPC Suffix Carriage Return Line Feed-Disabled by default in KBW Tab Prefix Tab Suffix “DE” Disable Command “FL” Laser Enable Command DTR Handshaking support RTS/CTS Handshaking Character...
  • Page 40 Appendix B – Default Settings (continued) PARAMETER 100 msec to Find Supplement Programmable in 100 msec steps (max 800 msec) Coupon Code 128 Programmable Code Lengths Programmable Prefix characters Suffix characters Prefixes for Individual Code types Editing Inter Scan-Code delay programmable (100 msec steps) Function/control Key...
  • Page 41 Appendix C The MS9520 and MS9540 scanner interfaces terminate to a 10-pin modular jack. The serial # label indicates the interface enabled when the scanner is shipped from the factory. MS9520-9 & MS9520-9 OCIA Function Ground RS-232 Transmit Output RS-232 Receive Input...
  • Page 42 Appendix C (continued) Cable Connector Configurations “Standard” PowerLink cable MLPN 53000 9-pin D-type female connector to the PC Function Shield Ground RS-232 Transmit Output RS-232 Receive Input DTR Input/Light Pen Source Power/Signal Ground Light Pen Data CTS Input RTS Output +5VDC 9-Pin D-Type Connector...
  • Page 43: Pin Assignments

    Appendix C (continued) Cable Connector Configuration The PowerLink cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. PowerLink Cable Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other.
  • Page 44: Warranty And Disclaimer

    The MS9500 scanners are manufactured by Metrologic at its Blackwood, New Jersey, USA facility. The MS9500 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS9500 scanners are free of all...
  • Page 45: Notices

    Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.
  • Page 46 Manuale può provocare dei raggi laser pericolosi per la vita. Il cliente non deve assolutamente tentare di riparare egli stesso lo scanner laser. Non guardate mai nel raggio laser, anche se credete che lo scanner non sia attivo. Non aprite mai lo scanner per guardare dentro l’apparecchio. Se tuttavia lo fate, potete esporVi a dei raggi laser pericolosi per la vita.
  • Page 47: Patents

    Appendix F Patents Patent Information This METROLOGIC product may be covered by one or more of the following US Patents: US Patent No. 4,958,984; 5,081,342; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468,951; 5,484,992; 5,525,789; 5,528,024; 5,591,953; 5,616,908; 5,627,359; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,811,780;...
  • Page 48: Addendum

    Addendum Addendum 1:1 If the optional power adapter available through Metrologic does not power the bar code scanner, the scanner will receive power from a host device such as a computer system. The following statement is applicable: Caution To maintain compliance with standards CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source must meet applicable performance requirements for a limited power source.
  • Page 49: Index

    Index AC input/outlet Accessories Approvals Audible Autodiscriminates Bar Code 1, 3, 10, 11, 12, 14,15 16 21, 24, 25, 26, 29, 42 Beep 3, 10, 11, 15, 16, 17, 23, 24 29, 31 Cable 2, 27, 29, 36, 37 communication 4, 11, 12, 17 27, 30 pin assignments...
  • Page 50 Index Razzberry tone 10, 12, 13, 31 Red LED 3, 10, 11, 17, 24 Repair RS-232 22, 27, 28, 30, 31, 32 33, 34, 35, 36 SELV Service Specifications Tones Transformers Troubleshooting 13, 38 Ventilation Voltage ii, 38 iv, 29 Warranty Window 10, 13...

Table of Contents