  • Page 1

    METROLOGIC INSTRUMENTS, INC. ® MS7120 Orbit Presentation Laser Scanner Installation and User’s Guide...

  • Page 3: Table Of Contents

    Copyright © 2003 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior written consent, except by reviewer, who may quote brief passages in a review, or provided for in the Copyright Act of 1976.

  • Page 4: Table Of Contents

    Operational Notes ...3 Installation For RS232, OCIA and IBM 46XX Interfaces...4 For Keyboard Wedge Interface ...5 For Stand Alone Keyboard Interface...6 Notes for USB Interface ...7 Notes for MS7120-00 'Laser Emulation' ...7 Scanner Parts...8 Audible Indicators...9 Visual Indicators ...10 Failure Modes...11 Labels...12 Maintenance...12...

  • Page 5: Introduction

    In addition, Orbit’s unique, contoured shape allows it to be picked-up and used as a hand-held scanner when scanning large or bulky items. Engineered with a large, easy-to-find optimal scan area, Orbit increases the first pass read rate for maximum productivity.

  • Page 6

    CCESSORIES Part # MS7120 Orbit 00-02407 MetroSelect 00-02408 MS7120 Installation and User’s Guide* Available on the Metrologic website - www.metrologic.com Part # AC to DC Power Transformer- Regulated 5.2VDC @ 650 mA output. 45-45593 120V United States 45-45591 220V-240V Continental European...

  • Page 7

    250 mA of current @ 5VDC. Orbit is shipped from the factory programmed with default settings. To configure the MS7120 scanner to meet the host system’s specific needs, refer to the MetroSelect Programming Guide ( enter the program mode and select the appropriate bar codes.

  • Page 8

    Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

  • Page 9

    Metrologic customer service representative. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

  • Page 10

    Metrologic customer service representative. Caution: To maintain compliance with applicable standards, all circuits connected to the scanner must meet the requirements for SELV (Safety Extra Low Voltage) according to EN 60950. To maintain compliance with standard CSA C22.2 No. 950/UL 1950 and norm EN 60950, the power source should meet applicable performance requirements for a limited power source.

  • Page 11

    If you recall defaults while re-configuring your scanner the Laser Emulation Mode will no longer be enabled. Scan the following barcode to re-enable the Laser Emulation interface. The scanner you are using must be labeled as an MS7120-00 to support this feature. USB I...

  • Page 12: Audible Indicators, Visual Indicators

    CANNER ARTS Red LED On a successful read of a bar code, the red LED will turn ON. After communication to the host is complete, the red LED will turn OFF. Refer to Visual Indicators and Audible Indicators for additional information. Green LED During normal operation, the green LED is ON.

  • Page 13

    UDIBLE NDICATORS When the MS7120 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect 00-02407B) or the MetroSet2 help files.

  • Page 14

    ISUAL NDICATORS There is a red LED and a green LED on the head of the MS7120. When the scanner is on, the flashing or constant illumination of the LEDs indicates the status of the current scan and the scanner.

  • Page 15

    Return the unit for repair at an authorized service center. Three Beeps - on power up If the scanner beeps 3 times on power up then, the nonvolatile memory that holds the scanner configuration has failed. Return the unit for repair at an authorized...

  • Page 16: Maintenance, Labels

    ABELS Each scanner has three labels on the bottom of the unit. These labels contain information such as; the model number, date of manufacture, serial number, laser class and caution statements. The following illustrations show the location and content of the three labels.

  • Page 17: Optimal High Density

    OLUME PECIFICATIONS Specifications based on 100% UPC Bar Codes. Optimal Low Density (Default) 190mm 60mm 100mm Scan Area Optimal High Density 215mm 60mm 105mm Scan Area...

  • Page 18: Normal

    OLUME PECIFICATIONS Specifications based on 100% UPC Bar Codes. Close 175mm 60mm Scan Area Normal 190mm 60mm Scan Area 95mm 100mm...

  • Page 19

    OLUME PECIFICATIONS Specifications based on 100% UPC Bar Codes. 215mm 75mm 105mm 75mm Scan Area...

  • Page 20: Optimal Low Density (default)

    EPTH OF IELD BY Optimal Low Density (Default) & & Minimum Bar Code Element Width mils INIMUM Width of Scan Field (mm) LEMENT IDTH Distance: Scanner Face To Bar Code (mm)

  • Page 21

    EPTH OF IELD BY & & Minimum Bar Code Element Width mils INIMUM Optimal High Density Width of Scan Field (mm) LEMENT IDTH Distance: Scanner Face To Bar Code (mm)

  • Page 22

    EPTH OF IELD BY Minimum Bar Code Element Width mils INIMUM Close Width of Scan Field (mm) LEMENT IDTH Distance: Scanner Face To Bar Code (mm)

  • Page 23: Normal

    EPTH OF IELD BY & & Minimum Bar Code Element Width mils INIMUM Normal Width of Scan Field (mm) LEMENT IDTH Distance: Scanner Face To Bar Code (mm)

  • Page 24

    EPTH OF IELD BY Minimum Bar Code Element Width mils INIMUM & Width of Scan Field (mm) LEMENT IDTH Distance: Scanner Face To Bar Code (mm)

  • Page 25

    NSTALLING THE Kit #45-45619 contains: Locking Plate 50-50302] ... Qty. 1 MLPN Base Cover 50-50301] ... Qty. 1 MLPN Wood Screw, #7 x 1.00” 18-18013] ... Qty. 3 MLPN Flathead Screw, M3 x 8 mm 18-18004] ... Qty. 4 MLPN Drill mounting holes Note the position Orbit will rest (fig.

  • Page 26: Troubleshooting Guide

    The following guide is for reference purposes only. Contact a Metrologic representative at 1-800-ID-METRO or 1-800-436-3876 to preserve the limited warranty terms on page 39. All Interfaces MS7120 Series Troubleshooting Guide SYMPTOMS POSSIBLE CAUSE(S) No LEDs, beep No power is being...

  • Page 27

    (Typical of Non- UPC/EAN codes.) (The scanner defaults to a minimum of 4 character bar code) If the scanner is setup to support ACK/NAK, RTS/CTS, XON/XOFF or D/E, verify that the host cable and host are supporting the handshaking properly Verify that the scanner’s data...

  • Page 28

    NOT incorrectly for others of the same bar code symbology Scanner beeps The scanner is not at some bar configured correctly codes and NOT for this type of bar for others of the code same bar code...

  • Page 29

    F0 break is transmitted. It may be necessary to try this in both settings. Enable Caps Lock detect setting of the scanner to detect whether the PC is operating in Caps Lock Try operating the scanner in Alt mode SOLUTION...

  • Page 30

    “RS-232" data Check that the scanner and the host are configured for the same interface font Add some intercharacter delay to the transmitted output by...

  • Page 31

    If the bar code data displays on the screen while using this program, it only demonstrates that the hardware interface and scanner are working.

  • Page 32

    7120 7120 7120 7120 The MS7120 Hand-Held Laser Scanner with Built-in PC Keyboard Wedge Interface is designed to be used for keyboard emulation only. Many RS-232 programmable functions available in other Metrologic scanners are also available as keyboard wedge functions.

  • Page 33

    Width-Orb: Width-Base: Weight: Termination: Cable: Tilt - Orb: MS7120 S VLD 640-660 nm 0 mm to 190 mm (0" to 7.5") at default (programmable) 1200 scans/second 5 fields of 4 parallel lines (omnidirectional) 0.13 mm (5.2 mil) Autodiscriminates all standard bar codes;...

  • Page 34

    Humidity: Light Levels: Shock: Contaminants: Ventilation: Specifications subject to change without notice. MS7120 S 5.2VDC ± 0.25V 1.1 W 220 mA (270 IBM) Class II; 5.2VDC@ 650 mA CDRH: Class IIa; EN 60825-1:1994/A11:1996 Class 1 FCC, ICES-003 & EN 55022 Class B 0°C to 40°C...

  • Page 35

    EFAULT ETTINGS Many functions of the scanner can be "programmed" - that is, enabled or disabled. The scanner is shipped from the factory programmed to a set of default conditions. The default parameter of the scanner has an asterisk ( * ) in the charts on the following pages. If an asterisk is not in the default column then the default setting is Off or Disabled.

  • Page 36

    EFAULT ETTINGS Parameter DTS/NIXDORF NCR F NCR S Poll Light Pen Source Beeper Tone Beep/Transmit Sequence Communication Timeout Razzberry Tone on Timeout Three Beeps on Timeout No Beeps on Timeout Enter Power Save Mode Same Symbol Rescan Timeout: 200 msecs Same Symbol Rescan Timeout: 500 msecs Programmable in 50 msec...

  • Page 37

    EFAULT ETTINGS Parameter Convert EAN-8 to EAN-13 Transmit UPC-A Number System Transmit UPC-A Manufacturer ID# Transmit UPC-A Item ID# Transmit Codabar Start/Stop Characters CLSI Editing (Enable) Transmit Mod 43 Check Digit on Code 39 Transmit Code 39 Stop/Start Characters Transmit Mod 10/ITF Transmit MSI-Plessey Check Characters Parity...

  • Page 38

    EFAULT ETTINGS Parameter Carriage Return Line Feed - disabled by default in KBW Tab Prefix Tab Suffix "DE" Disable Command "FL" Laser Enable Command DTR Handshaking Support RTS/CTS Handshaking Character RTS/CTS Message RTS/CTS XON/XOFF Handshaking ACK/NAK Two Digit Supplements Five Digit Supplements Bookland 977 (2 digit) Supplemental Requirement...

  • Page 39

    EFAULT ETTINGS Parameter Coupon Code 128 Programmable Code Lengths Programmable Prefix Characters Suffix Characters Prefixes for individual Code Types Editing Inter Scan-Code Delay Programmable (100 msec steps) Function/Control Key Support Minimum Element Width Programmable in 5.6 µsec steps Depth of Field Variable Depth of Field Normal Depth of Field Extended Depth of Field...

  • Page 40

    CANNER AND ABLE Scanner Pinout Connections The MS7120 scanner interfaces terminate to a 10-pin modular jack. The serial # label indicates the interface enabled when the scanner is shipped from the factory. Some units have internal jumpers that can be moved to enable a different electrical interface.

  • Page 41

    CANNER AND ABLE MS7120-11 IBM 46XX/RS-232 Function Ground RS-232 Transmit Output RS-232 Receive Input RTS Output CTS Input DTR Input IBM 46XX transmit IBM 46XX Receive +5VDC Shield Ground Options listed are program/cable selections Cable Connector configurations PowerLink Cable 54-54xxx* or 53-53xxx*...

  • Page 42

    CANNER AND ABLE Cable Connector Configuration The PowerLink cable is terminated with a 5-pin DIN female connector on one end, and a 6-pin mini DIN male on the other. PowerLink Cable Metrologic will supply an adapter cable with a 5-pin DIN male connector on one end and a 6-pin mini DIN female connector on the other.

  • Page 43: 82178 Puchheim B

    The MS7120 Orbit scanners are manufactured by Metrologic at its Blackwood, New Jersey, U.S.A. facility. The MS7120 scanners have a two (2) year limited warranty from the date of manufacture. Metrologic warrants and represents that all MS7120 scanners are free of all defects in material, workmanship and design, and have been produced and labeled in compliance with all applicable U.S.

  • Page 44: Notices

    Never attempt to look at the laser beam, even if the scanner appears to be nonfunctional. Never open the scanner in an attempt to look into the device. Doing so could result in hazardous laser light exposure. The use of optical instruments with the laser equipment will increase eye hazard.

  • Page 45

    The following notice applies to Model number MS7120-11 only. For Class B compliance with FCC Part 15, ICES-003, and EN55022, attach the provided ferrite choke to the PowerLink cable shipped with your MS7120-11 bar code scanner. Ferrite Choke Installation: 1.

  • Page 46

    Klappen Sie die beiden Hälften des Ferritkern Ver-schlusses zusammen. Le seguenti informazioni sono valide solo per il modello MS7120-11 Per essere conformi alla Classe B delle norme FCC Parte 15, ICES-003, e EN55022, occorre attaccare, al cavo dati/alimentazione inviato con l’MS7120- 11, il nucleo di Ferrite allegato.

  • Page 47

    OTICES Nota (exclusivamente para los modelos de la serie MS7120-11) De acuerdo con las normativas FCC apartado 15, ICES-003 y EN55022 para la Clase B, el obturador de ferrita del PowerLink que se suministra con el modelo de lector de códigos de barras MS7120-11.

  • Page 48: Patents

    ATENTS “Patent Information This METROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 4,960,985; 5,081,342; 5,216,232; 5,260,553; 5,340,971; 5,424,525; 5,484,992; 5,525,789; 5,528,024; 5,557,093; 5,616,908; 5,627,359; 5,637,852; 5,661,292; 5,777,315; 5,789,730; 5,789,731; 5,811,780; 5,828,048; 5,844,227; 5,925,870; 6,029,894; 6,098,885; 6,209,789; 6,257,492;...

  • Page 49: Design Specifications, Index

    NDEX accessories... 2, 3 adapter... 2, 3, 5, 38 application... 27 audible ... 9 authorized service center... 11 autodiscriminates... 29 bar code...1, 3, 8-10, 12-20, 23-25, 27, 29, 41 beep... 4, 9, 10, 22, 23, 29, 32 cable ... 2-6, 22, 23, 26, 29, 36-38, 41, 43 caution ...

  • Page 50

    RMA... 39 RS-232...1, 2, 3, 26-29, 31-37 scan lines... 29 scan pattern... 8, 29 scan speed ... 29 scanner installation... 4, 5, 6 SELV ... 4, 5, 6 shock ... 30 specifications ... 13-15, 29, 30 stand... 2, 3, 6, 29 storage...

  • Page 52

    July 2003 Printed in USA 0 0 - 0 2 4 0 8 B...

Comments to this Manuals

Symbols: 0

Latest comments:

×

Select the desired size and copy embed code

Copy your embed code and put on your site: