  • Page 1 DE 4002 www.karcher.com 5.959–155 A 2001026 (04/03)
  • Page 2: Starting The Unit

    English 1. Starting the unit...
  • Page 3 DE 4002 1. Starting the unit 1.2 Attaching the accessories 1 Steam pistol 2 Handwheel for steam control • Connect the modular accessory plug to the main 3 Release button unit. The lugs on the plug must lock into place on 4 Locking mechanism (child lock) the cover of the main unit socket.
  • Page 4 English 1. Starting the unit 1.4 Switching the unit ON 1.6 Switching the unit OFF • Plug the unit into a mains socket, and switch it • Switch the unit OFF by means of switches. on by means of the steam supply switch and the •...
  • Page 5: Directions For Use

    DE 4002 2. Directions for use 2.1 Important fundamental information 2.3 Regulating volume of steam with rotary knob on main unit To achieve satisfactory results with a steam cleaner, it is most important that the initial cleaning • If you are working with the standard accessories stage is performed thoroughly.
  • Page 6 English 2. Directions for use 2.6 Temperature indicator 2.9 Floor nozzle • This indicator shows you whether you are • Depending upon the actual cleaning task, the floor working within the proper temperature range nozzle can be used with the extension tubes. You (green area).
  • Page 7 DE 4002 2. Directions for use – As soon as the lamp on the iron extinguishes, it Wallpaper remover (Order no. 2.863-076) is ready for use. With the wallpaper remover you can use the steam – As soon as you press the switch, a solenoid cleaner for stripping wallpaper.
  • Page 8: Care, Maintenance & Troubleshooting

    English 3. Care, Maintenance & Troubleshooting 3.1 Cleaning the boiler The safety cap must not be attached to the boiler while descaling is being carried out. Make sure that the cleaner can not be used while there is any descaling solution left in the boiler. •...
  • Page 9: Safety Devices

    DE 4002 4. Safety devices This steam cleaner has been fitted with various 4.3 Safety thermostat safety devices to provide multiple protection If the low-water thermostat fails and the cleaner measures. The most important safety components overheats, then the safety thermostat switches the are described below.
  • Page 10: Technical Specifications

    English 5.959-155 6. Technical specifications 8_XVge\VT_VbaaXVg\ba Ib_gTZX %&#ž%'# 6heeXagglcX $q(#")# Ib_gTZXTg[TaWZha @T\afVbaaXVg\baVTU_XBeWXeab! 8H)!)'**(* 67A)!)'**,$ 6;)!)'*+&% :5)!)'*+&$ 4HF)!)'*+&& 6F467A)!)'*,%# 5E)!)'*+(# CXeYbe`TaVXWTgT ;XTgXecbjXeVbafh`cg\ba %%(# $+## Ch`c @Tk!bcXeTg\aZceXffheX &!% &!% CXe`\ff\U_XbcXeTg\aZceXffheX ;XTg\aZg\`X VT!'!( VT!(!( `\a"?jTgXe @Tk!fgXT`ib_h`X Z"`\a 7\`Xaf\baf JX\Z[gj\g[bhgTVVXffbe\Xf JTgXeVTcTV\gl GTa^VTcTV\gl 5b\_XeVTcTV\gl J\Wg[ &#( &#( ?XaZg[...
  • Page 11 DE 4002 1.092-100.0 * EUR 1.092-280.0 * GB 1.092-290.0 * CH 4.590-078.0 1.092-600.0 * AUS 1.092-700.0 * CSA-CDN 1.092-720.0 * BR 6.362-927.0 4.075-010.0 5.115-696.0 5.363-368.0 4.321-114.0 6.362-922.0 5.321-529.0 4.127-015.0 5.321-529.0 4.013-026.0 4.127-015.0 5.515-108.0 5.044-239.0 6.435-250.0 7.303-119.0 6.362-922.0 08.04.2003...