Burnham 5B Series User's Information Manual

Gas - fired boiler

Advertisement

USER'S INFORMATION MANUAL
WARNING:
If the information in this
manual is not followed exactly, a fire or
explosion may result causing property
damage, personal injury or loss of life.
-
Do not store or use gasoline or other
flammable vapors and liquids in the
vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do
not use any phone in your building.
Immediately call your gas supplier
from a neighbor's phone. Follow the
gas supplier's instructions.
If you cannot reach your gas supplier,
call the fire department.
-
Installation and service must be
performed by a qualified installer,
service agency or the gas supplier.
8141303R6 - 8/15
SERIES 5B
Gas - Fired Boiler
AVERTISSEMENT.
suivre les instructions données dans cette
notice pour réduire au minimum le risque
d'incendie ou d'explosion ou pour éviter
tout dommage matériel, toute blessure ou
la mort.
-
Ne pas entreposer ni utiliser d'essence ni
d'autres vapeurs ou liquides inflam-mables
dans le voisinage de cet appareil ou de tout
autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR
DE GAZ:
Ne pas tenter d'allumer d'appareils.
Ne touchez à aucun interrupteur. Ne pas
vous servir des téléphones dans le
bâtiment où vous vous trouvez.
Appelez immédiatement votre
fournisseur de gaz depuis un voisin.
Suivez les instructions du fournisseur.
Si vous ne pouvez rejoindre le
fournisseur de gaz, appelez le service
des incendies.
-
L'installation et I'entretien doivent être
assuréx par un installateur ou un service
d'entretien qualifié ou par le fournisseur de
gaz.
BOILER NOT FOR INSTALLATION ON COMBUSTIBLE
FLOORS UNLESS FLOOR SHIELD OR NATIONAL BUILDING
CODE APPROVED MATERIALS ARE INSTALLED BETWEEN
BOILER AND FLOOR.
Commercial Boilers
www.burnhamcommercial.com
Assurez-vous de bien

Advertisement

Table of Contents
loading

Summary of Contents for Burnham 5B Series

  • Page 1 USER'S INFORMATION MANUAL SERIES 5B Gas - Fired Boiler WARNING: If the information in this AVERTISSEMENT. Assurez-vous de bien suivre les instructions données dans cette manual is not followed exactly, a fire or notice pour réduire au minimum le risque explosion may result causing property d'incendie ou d'explosion ou pour éviter damage, personal injury or loss of life.
  • Page 2 The following terms are used throughout this manual to bring attention to the presence of hazards of various risk levels. Indicates a potentially hazardous situation which, Indicates a potentially hazardous situation which, if not avoided, could result in death, serious injury if not avoided, may result in moderate or minor or substantial property damage.
  • Page 3: Basic Operation

    Basic Operation Should overheating occur or the gas supply fail to shut off, do not turn off or disconnect the electrical supply to the pump. Instead, shut off the gas supply at a location external to the appliance. En cas de surchauffe ou si I'admission de gaz ne peut étre coupée, ne pas couper ni débrancher l'alimentation électrique de la pompe.
  • Page 4: For Your Safety Read Before Operating

    FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. If you cannot reach your gas supplier, call the A. This appliance is equipped with an ignition device fire department.
  • Page 5 FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. A. This appliance is equipped with an ignition device BEFORE OPERATING smell all around the appliance area which automatically lights the pilot.
  • Page 6 FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury, or loss of life. A. This appliance is equipped with an ignition device BEFORE OPERATING smell all around the appliance which automatically lights the pilot.
  • Page 7 Figure 5: EI Control Locations (USA Only: 5006 thru 5009) Figure 6: EI Control Locations (USA Only: 5010 thru 50026) Canada: All Figure 7: EP Control Locations...
  • Page 8: User Maintenance

    User Maintenance Service on this boiler should be undertaken only by trained and skilled personnel from a qualified service agency. Inspections should be performed at intervals specified in Installation, Operating and Service Instructions and this manual. Maintain manuals in a legible condition. Keep boiler area clear and free of combustible materials, gasoline and other flammable vapors and liquids.
  • Page 9 Figure 8: Recommended Vent Systems Figure 10: Typical Main Burner Flame Figure 9: Typical Pilot Flame...
  • Page 10 If access to the flue cleanout panels facing the front Examination of Flue Product Carrying Areas. of the boiler is required, the front vestibule panel 1. Boiler must be removed. See Figure 11. Flue passageways in the boiler sections should be Remove the Front Cleanout Panels first by removing checked annually for any blockage or accumulation the upper and lower nuts and washers securing these...
  • Page 12 All Series 5B repair parts may be obtained through your local Burnham Wholesale distributor. Should you require assistance in locating a Burnham distributor in your area, or have questions regarding the availability of Burnham products or repair parts, please contact Burnham Customer Service at...

Table of Contents