SECO-LARM Enforcer E-921CPQ Manual

Voice dialer

Advertisement

Quick Links

ENFORCER Voice Dialer

Troubleshooting:

• Try re-entering the PIN number to ensure that you have
entered it correctly.
• While pressing and holding the [PROG] button, use a pen or
Dialer will not arm/disarm
paper clip to press the [RESET] button on the back of the
dialer. This sets the PIN number to the default (000).Then try
to arm/disarm again.
• Make sure that the telephone line is working.
• Make sure that you have programmed at least one
telephone number into the unit and that the full number has
been stored.
Dialer will not dial out
• Make sure that the system is in Auto Dial mode.
• Ensure that the line to the wall jack is plugged into the
dialer's "LINE" jack, and any phone extension connected to
the dialer is plugged into the dialer's "TEL" jack.
• Check to see if another unit (fax or answering machine)
Unit doesn't respond to a call-
could be answering the call and remove the other unit.
back
• Adjust the call-in ring detect setting so the dialer will answer.
Difficulty in activating 'room
• Try pressing the code key again.
monitor' by telephone remote
• Move to a quieter location as ambient noise may affect the
control
dialer's ability to detect the tone signal.
While the system can provide valuable protection to home and property when properly installed, it
NOTE:
cannot guarantee complete protection against intrusion. SECO- LARM is not responsible for any losses or
damage which may occur during the use of this product.
Users and installers of this product are responsible for ensuring this product complies with all
IMPORTANT:
national, state, and local laws and statutes related to monitoring and recording audio and video signals.
SECO-LARM will not be held responsible for the use of this product in violation of any current laws or
statutes.
WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while
used in normal service for one (1) year from the date of sale to the original customer. SECO- LARM's
obligation is limited to the repair or replacement of any defective part if the unit is returned, transport ation
prepaid, to SECO-LARM. This Warranty is void if damage is caused by or attributed to acts of God, physical
or electrical misuse or abuse, neglect, repair or alteration, improper or abnormal usage, or faulty installation,
or if for any other reason SECO-LARM determines that such equipment is not operating properly as a re sult
of causes other than defects in material and workmanship. The sole obligation of SECO- LARM and the
purchaser's exclusive remedy shall be limited to the replacement or repair only, at SECO- LARM's option. In
no event shall SECO-LARM be liable for any sp ecial, collateral, incidental, or consequential personal or
property damage of any kind to the purchaser or anyone else.
NOTICE: The information and specifications printed in this manual are current at the time of publication.
However, the SECO-LARM policy is one of continual development and improvement. For this reason,
SECO-LARM reserves the right to change specifications without notice. SECO-LARM is also not responsible
for misprints or typographical errors.
Copyright © 2014 SECO-LARM U.S.A., Inc. All rights reserved. This material may not be reproduced or
copied, in whole or in part, without the written permission of SECO-LARM.
®
SECO-LARM
U.S.A., Inc.
16842 Millikan Avenue, Irvine, CA 92606
Phone: (949) 261-2999 | (800) 662-0800
16
Website: www.seco-larm.com
Email: sales@seco-larm.com
MiE-921CPQ_141204.docx
SECO-LARM U.S.A., Inc.
When triggered by an alarm system, the ENFORCER Voice Dialer can call up to 5 numbers and deliver
a user-recorded 20-second voice message, playing repeatedly for one minute. Each number can
contain up to 32 digits, including #, tones, and pauses. T he LCD shows the number being dialed at each
stage of the dialing process. The receiver can then listen in or broadcast a message to the room
occupants or can disarm the system. The same functions are available by remote call in as well as
arming the system. The dialer includes a home mode (acting like a door chime when the owner is
present) and a panic button. The 105dB built-in siren alarm can be programmed on or off.
®
PIHLK1
Voice Dialer
Manual
Models Available
Certification
E-921CPQ
E-921KPQ

Advertisement

Table of Contents
loading

Summary of Contents for SECO-LARM Enforcer E-921CPQ

  • Page 1: Troubleshooting

    IMPORTANT: national, state, and local laws and statutes related to monitoring and recording audio and video signals. SECO-LARM will not be held responsible for the use of this product in violation of any current laws or statutes. WARRANTY: This SECO-LARM product is warranted against defects in material and workmanship while used in normal service for one (1) year from the date of sale to the original customer.
  • Page 2: Table Of Contents

    • Built-in 105dB alarm (with programmable alarm on/off) • Built-in auxiliary output for external alarm or siren • Built-in line seizure For a complete listing of SECO-LARM products, please visit us online at www.seco-larm.com. SECO-LARM U.S.A., Inc. SECO-LARM U.S.A., Inc.
  • Page 3: Parts List

    7M7TE02BE921CPQ does not di sable your alarm equipment. If you have questions about what will disable alarm examples only: For other sensors and products available from SECO-LARM, please visit our website at www.seco-larm.com. equipment, consult your telephone company or a qualified installer.
  • Page 4: Overview

    Note: The Voice Dialer uses EEPROM to retain memory in the event of a power loss. 3. Set the number of Call-in rings to be less than the voicemail or message answer point. SECO-LARM U.S.A., Inc. SECO-LARM U.S.A., Inc.
  • Page 5 “beeps” and automatically hang up. slide down. Check that the unit is firmly attached and tighten or loosen the screws as needed. 10. Once all connections are made, the dialer is ready to be programmed. SECO-LARM U.S.A., Inc. SECO-LARM U.S.A., Inc.
  • Page 6: Programming The Voice Dialer

    ‘12145552858,’ press the [DEL/PAUSE] button for 2 seconds until the and the user must dial in again. letter ‘F’ appears on the LCD screen, enter ‘205’ and press the [ARM/DISARM] button. SECO-LARM U.S.A., Inc. SECO-LARM U.S.A., Inc.
  • Page 7: Deleting A Stored Phone Number

    [ARM/DISARM] button to accept. 4. Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] button until the programming icons disappear to exit the setup mode. SECO-LARM U.S.A., Inc. SECO-LARM U.S.A., Inc.
  • Page 8: Setting The Auto Dial Function

    4. Press the [#/DOWN] or [*/UP] button to select other setup categories or press the [PROG] 2. To listen to a message, press the [REC/PLAY] button. button until the programming icons disappear to exit the setup mode. SECO-LARM U.S.A., Inc. SECO-LARM U.S.A., Inc.

This manual is also suitable for:

Enforcer e-921kpq

Table of Contents