McDATA Sphereon 4500 User Manual page 181

Fabric switch
Hide thumbs Also See for Sphereon 4500:
Table of Contents

Advertisement

Action
Message
Description
Action
Message
Description
Action
Message
Description
Action
Message
Description
Action
R
Message
Description
Action
Review the Switch Binding Membership List to determine if the
devices should be members.
Port diagnostics cannot be performed on an inactive port.
This displays when port diagnostics is run on a port in an inactive
state.
Run the diagnostics on an active port.
Port speeds cannot be configured at a higher rate than the
director/switch speed.
This displays when you configure a port to 2 GB/sec and the switch
speed is set to 1 Gb/sec.
Set the port speed to 1 Gb/sec in the Configure Ports dialog box.
Product Manager error <number>.
The switch Product Manager encountered an internal error and
cannot continue.
Report the problem to support personnel.
Product Manager instance is currently open.
A Product Manager window is currently open.
Informational message only.
R_A_TOV must be greater than E_D_TOV.
R_A_TOV must be greater than E_D_TOV.
Change one of the values so that R_A_TOV is greater than E_D_TOV.
Product Manager Messages