Download Print this page

Bosch DS840 Installation Instructions

Tritechpir/microwave intrusion detectors

Advertisement

Quick Links

Installation Instructions
DS825, DS825T, DS840, DS840T
TriTech PIR/Microwave Intrusion Detectors
1.0
General Information
The DS825 Series and DS840 Series are microprocessor-based
TriTech Passive Infrared/Microwave Intrusion Detectors that provide
immunity to false alarms caused by pets [a dog up to 100 lbs.
(45 kg) or up to 10 cats, and other small animals such as birds
and rodents]. Patented Passive Infrared and Microwave signal
processing provides excellent catch performance with freedom
from false alarms.
2.0
Specifications
• Input Power:
• Standby Power:
• Alarm Relay:
• Temperature:
• Microwave Frequency:
DS825(T)/DS840(T):
DS825TA/DS840TA:
DS825TB/DS840TB:
• Coverage:
DS825 Series:
DS840 Series:
• Internal Pointability:
• Optional Tamper:
• Options:
Reading Bosch Security Systems, Inc. Product Date Codes
For Product Date Code information, refer to the Bosch Security
Systems, Inc. Web site at:
http://www.boschsecurity.com/datecodes/
6 to 15 VDC, 15 mA DC nominal (up to
35 mA DC during walk testing).
No internal standby battery. Connect to
DC power sources capable of supplying
standby power. For each hour of
standbytime needed, 15 mAh are
required. For UL Listed Requirements,
four hours (60 mAh) are required.
Silent operating Normally Closed reed
relay. Contacts rated 3 W, 125 mA,
28 VDC maximum for DC resistive
loads; and protected by a 4.7
resistor in the common "C" leg of the
relay. Do not use with capacitive or
inductive loads.
-40°F to +120°F (-40°C to +49°C). For
UL Certificated Installations, the
temperature range is +32°F to +120°F
(0°C to +49°C).
10.525 GHz (UL Listed)
10.687 GHz (Export only, not UL Listed)
9.9 GHz (Export only, not UL Listed)
25 ft. x 25 ft. (8 m x 8 m)
40 ft. x 40 ft. (12 m x 12 m)
+1° to –18° Vertical.
The DS825T, DS825TA, DS825TB,
DS840T, DS840TA, and DS840TB
have a Normally Closed (with cover on)
tamper switch. Contacts rated at
28 VDC, 125 mA max. Connect the
tamper circuit to a 24-hour protection
circuit.
B335 Low Profile Swivel Mount Bracket
and B338 Ceiling Mount Bracket. (The
use of brackets may reduce range and
increase dead zone areas.)
• Compliance:
Rules and with RSS-210 of Industry and Science Canada.
Operation is subject to the following two conditions:
(1)
interference, and
interference received, including interference that may cause
undesirable operation.
Changes or modifications not expressly approved by Bosch Security
Systems can void the user's authority to operate the equipment.
3.0
Mounting
3.1
Mounting Considerations
• Never install the detector in an environment that causes a constant
alarm in one technology; it should never be left to operate with
the tri-color LED in a constant green, yellow, or red condition. A
detector with one technology in constant alarm, will cause an
alarm output whenever the other technology alarms. Good
installations start with the LED OFF when there is no target motion.
The best installations will have background noise voltages below
recommended limits.
• Point the unit away from outside traffic (e.g. roads, alleys, and
parking lots).
NOTE: Microwave energy will pass through glass and most
common non-metallic construction walls.
• Avoid direct or indirect sunlight.
,1/2 W
• Point the unit away from glass exposed to the outdoors and objects
that may change temperature rapidly.
NOTE: The PIR detector will react to objects rapidly changing
temperature within its field-of-view.
• Eliminate interference from nearby outside sources.
• Avoid installations where rotating machines (e.g. ceiling fans) are
normally in operation within the coverage pattern.
• Select a location likely to intercept an intruder moving across
the coverage pattern.
• The surface should be solid and vibration-free.
• Mounting height range is 6 to 8 ft. (1.8 to 2.4 m). The
recommended height is 7.5 ft. (2.3 m). Mounting height for Pet
Applications is 6.5 ft. (2 meters).
3.2
Mounting the Detector
• Remove the cover by inserting a thin flathead screwdriver into
the locking tab hole at the bottom front of the detector, pressing
in, and pulling the cover up and forward.
NOTE: Mount the unit with the terminal block up.
• Remove the circuit board from the base by pulling outward slightly
on one of the Circuit Board Locking Tabs (see Figure A).
LED Jumper
Cable Knockout
Terminal
Block
LED
Circuit Board
Locking Tab
(One on
Each Side)
Mirror
Assembly
Figure A - Location of Features
• Remove the mirror.
This device complies with Part 15 of the FCC
this device may not cause harmful
(2)
this device must accept any
Microwave
Adjustment
Tamper
Terminals
Circuit Board
Retainer Tabs (2)
Bracket Mounting
Hole
Surface
Mounting
Holes (4)
Rear enclosure and mounting holes
Wiring
Knockouts
Mirror
Tracks (2)
Corner
Mounting
Holes (2)

Advertisement

loading

Summary of Contents for Bosch DS840

  • Page 1 Retainer Tabs (2) increase dead zone areas.) • Reading Bosch Security Systems, Inc. Product Date Codes Circuit Board Locking Tab For Product Date Code information, refer to the Bosch Security Mirror Bracket Mounting (One on Each Side) Tracks (2) Hole Systems, Inc.
  • Page 2 Range Adjust slightly. Continue walk testing (waiting one minute tricolor LED from indicating a after removing/replacing the cover) and adjusting the range until supervision trouble condition. the farthest edge of desired coverage has been accurately placed. Page 2 © 2011 Bosch Security Systems, Inc. DS825-825T-840-840T Installation Instructions...
  • Page 3 Containing Pets movement outside of the intended coverage pattern. The DS825, DS825T, DS840 and DS840T detectors will provide reasonable protection from nuisance alarms caused by the following • Walk test the unit from all directions to determine all the pattern sources: boundaries.
  • Page 4 Meter Feet Mirror adjusted to -6° DS840 Coverage Meters Feet Side View Meter Feet Mirror adjusted to -4° © 2011 Bosch Security Systems, Inc. 2/11 130 Perinton Parkway, Fairport, New York 14450 DS825-825T-840-840T Installation Instructions www.boschsecurity.com P/N: F01U034969-11 Page 4...

This manual is also suitable for:

Ds825Ds840tDs825t