Download Print this page
Panasonic CX-41 Series Instruction Manual
Panasonic CX-41 Series Instruction Manual

Panasonic CX-41 Series Instruction Manual

Amplifier built-in small photoelectric sensor

Advertisement

Quick Links

INSTRUCTION MANUAL
MJECK-CX400 No.0096-99V
Thank you very much for purchasing Panasonic products.
Read this Instruction Manual carefully and thoroughly for
the correct and optimum use of this product. Kindly keep
this manual in a convenient place for quick reference.
Please refer "
".
If you could not visit our web site, contact our sales of-
WARNING
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use prod-
ucts which meet laws and standards, such as OSHA, ANSI or IEC
etc., for personnel protection applicable in each region or country.
Stability indicator (Green) (Note 1)
Operation indicator (Orange) (Note 2)
Lights up under the stable light
Lights up when the sensing out-
condition or the stable dark condition
put is ON
Sensitivity adjuster (Note 1, 3)
Operation mode switch (Note 1, 3)
Sensing range be-comes longer
L: Light-ON
when turned clockwise
D: Dark-ON
Notes: 1) Not incorporated on the thru-beam type sensor emitter.
2) It is the power indicator (green: lights up when the power is ON) for the
thru-beam type sensor emitter.
3) Not incorporated on the basic type sensor.
MOUNTING
The tightening torque should be
M3 (length 12mm)
screw with washers
0.5N·m or less.
Optimum sensing is possible when
the position of the transparent
sensing object is set at the center
If the sensing position is set near the
or the re-
3
(Brown) +V
(Brown) +V
Load
(Black)
+
+
Output (Note)
(Black)
-
-
Output (Note)
Load
(Blue) 0V
(Blue) 0V
Note: The thru-beam type sensor emitter does not incorporate the output.
1. Turn the sensitivity adjuster fully counterclock-
wise to the minimum sensitivity position, MIN.
2. In the light received condition, turn the sen-
sitivity adjuster slowly clockwise and con-
firm the point A where the sensor enters
the "Light" state operation.
3. In the dark condition, turn the sensitivity
adjuster further clockwise until the sensor en-
ters the "Light" state operation and then bring
where the sensor
just returns to the "Dark" state operation.
If the sensor does not enter the "Light" state
operation even when the sensitivity adjuster is
turned fully clockwise, the position is point .
4. The position at the middle of points A and
is the optimum sensing position.
5
CAUTIONS
This product has been developed / produced for industrial use only.
Make sure to carry out wiring in the power supply OFF condition.
Take care that wrong wiring will damage the sensor.
Verify that the supply voltage variation is within the rating.
If power is supplied from a commercial switching regula-
tor, ensure that the frame ground (F.G.) terminal of the
power supply is connected to an actual ground.
In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the
frame ground (F.G.) terminal of the equipment to an actual ground.
Extension up to total 100m (each emitter and receiver of
thru-beam type), or less, is possible with 0.3mm
of conductor area cable.
Make sure that stress by forcible bend or pulling is not
applied directly to the sensor cable joint.
Do not run the wires together with high-voltage lines or power lines or put
them in the same raceway. This can cause malfunction due to induction.
Do not use during the initial transient time (50ms) after
the power supply is switched ON.
Sensor
lamp from a rapid-starter lamp, a high frequency lighting de-
mounting
racket
This sensor is suitable for indoor use only.
(Optional)
Do not use this sensor in places having excessive vapor, dust,
etc., or where it may come in contact with corrosive gas, etc.
Take care that the sensor does not come in contact with oil, grease,
organic solvents such as thinner, etc., strong acid, or alkaline.
This sensor cannot be used in an environment contain-
Never disassemble or modify the sensor.
Panasonic Industry Co., Ltd.
Panasonic Industry Co., Ltd. 2024
A
Optimum position
A
Web
IEC
2
, or more
1
3
1
2
3
3
NPN
V
1
0V
1
PRINTED IN JAPAN
1.
2. "
"
3. "
B
4. A
B
5
OSHA
ANSI
2
ON
1
3
L
ON
D
ON
0.5N m
M3
12mm
PNP
V
1
0V
Panasonic Industry Co., Ltd. 2024
MIN
A
A
"
"
"
B
A
/
F.G.
F.G.
0.3mm
2
100m
50ms

Advertisement

loading

Summary of Contents for Panasonic CX-41 Series

  • Page 1 MJECK-CX400 No.0096-99V firm the point A where the sensor enters the “Light” state operation. Thank you very much for purchasing Panasonic products. 3. “ ” Read this Instruction Manual carefully and thoroughly for 3. In the dark condition, turn the sensitivity the correct and optimum use of this product.
  • Page 2 [A(1 ) B(2 ) C(3 )· · · · ·L(12 )] [A(’10 ) B(’11 ) C(’12 )· · · · ·J(’19 )] [0(’20 ) 1(’21 ) 2(’22 )· · · · ·9(’29 )] Panasonic Industry Co., Ltd. Panasonic Industry Co., Ltd. 2024 Panasonic Industry Co., Ltd. 2024...

This manual is also suitable for:

Cx-42 seriesCx-46 seriesCx-48 seriesCx-49 seriesCx-400